Excessive ventilation when utilizing a bag-valve mask device (BVM) can cause:

Answer :

Excessive ventilation when utilizing a Bag-Valve Mask device (BVM) can cause several adverse effects, including barotrauma, volutrauma, and decreased cardiac output.

Barotrauma occurs when the high pressure from over-ventilation leads to damage in the lungs and surrounding structures, such as the alveoli and interstitial tissues. Volutrauma is the result of overdistension of the alveoli, causing injury to the lung tissues. Both barotrauma and volutrauma can contribute to the development of Acute Respiratory Distress Syndrome (ARDS), a life-threatening condition.

Additionally, excessive ventilation with a BVM can cause decreased cardiac output, which is the amount of blood the heart pumps in one minute. This occurs due to the increased intrathoracic pressure that hinders venous return to the heart. As a result, the heart cannot pump sufficient blood to meet the body's needs, leading to hypotension and reduced organ perfusion.

To prevent these complications, it is essential to provide appropriate ventilation rates and volumes using a BVM. For adults, the recommended rate is 10-12 breaths per minute, with a tidal volume of 500-600 mL. Proper training and regular practice with the BVM can ensure healthcare providers deliver safe and effective ventilation to patients in need.